Manufacturers: HOCHIKI
Origin: Canada
DESCRIPTION:
Hochiki’s HCP-1000 Series microprocessor based fire alarm control panels are multi-zone units designed for maximum flexibility and easy installation and operation. Fully configurable from the front panel using push buttons and DIP switches, the HCP-1000 Series enables the user to configure the system to meet their specific requirements. With a large capacity of supervised Class A (Style D) or Class B (Style B) initiating circuits and supervised Class A (Style Z) or Class B (Style Y) indicating circuits, the HCP-1000 Series is designed to meet virtually all applications.
The HCP-1000 Series consists of a main fire alarm chassis which houses and controls all other modules. Additional modules may be installed to configure the system to meet any requirements that the user may have. The HCP-1000 Series allows for additional indicating circuits, initiating circuits and relay modules to be added to the system.
Equipped with configuration DIP switches on the main display module, the HCP-1000 Series fire alarm control panels are configured through a combination of DIP switch and button settings. Through this configuration method the user can define the system as a Single Stage or Two Stage operation as well as perform various functions such as a One Man Walk Test.
STANDARD FEATURES
UL 864 9th edition Listed
Large system capacity
Modular design
Each indicating circuit can be configured as Silence Able or Non-Silence Able
Audible may be configured as Steady, Temporal Code, California Code or March Time
Each initiating circuit can be configured as Alarm, Supervisory, Waterflow or Trouble
Two LEDs per initiating circuit; one for Trouble and one for Status
Initiating and indicating circuits may be individually disconnected by a DIP switch
Configurable Signal Silence Inhibit, Auto Signal Silence, Two-Stage Operation and One Man Walk Test
Subsequent Alarm, Supervisory and Trouble operation
Two outputs for 4 wire resettable smoke power supply (200 mA Max. each)
Auxiliary relay contacts for Common Alarm and Common Supervisory as well as a Common Trouble Relay (Each relay contact Form C, 28 VDC @ 1 Amp (resistive))
RS-485 Interface for HRA-1000 Remote Multiplex Annunciators
Interface for Remote Trouble Indicator
Easy configuration via push buttons and DIP switches on the front panel
Fully site or field programmable indicating circuits and auxiliary relays
Extensive transient protection
Slide-in labels for zone identification
6 Amp or 12 Amp power supplies available
Removable door for easy installation and servicing
Removable terminal blocks for easy wiring and servicing.